Analysis and engineering notes on AI data center infrastructure — power, cooling, racks and the build-out of compute capacity worldwide.

Container Data Center Exterior Coating: Application and Upkeep

Shopify API

Container data center shells live or die by their paint. The application process - spray parameters on corrugated panels, stripe coats, recoat windows - sets the starting quality; the washdown, inspection grading (ASTM D610/D714), and spot-repair rhythm dec...

container data centercorrosionISO 12944maintenanceprotective coating

Read article →

Welding Outdoor Cooling Tower Piping: Process Requirements

Shopify API

Field welding requirements for outdoor cooling tower and condenser-water piping: ASME B31.9, ASME Section IX qualifications, fit-up tolerances, galvanized coating removal and A780 repair, cold-weather preheat, spot RT and the 1.5x hydro test.

ASME B31.9ASME Section IXcondenser watercooling towerdata center coolinggalvanized steelhydrostatic testpipe welding

Read article →

The 2-Year Math on Renting Out GPU Compute in the US

Shopify API

A reproducible two-year ROI model for US GPU compute rental: the H100/B200 rate ladder, $0.49 per GPU-hour of real operating cost, utilization sensitivity, and the residual-value debate that decides the return.

AI infrastructureB200colocationcompute economicsGPU cloudGPU rentalH100ROI

Read article →

How a Solid-State Transformer Works: SST in 800 VDC Data Centers

Shopify API

Stage-by-stage working principle of the solid-state transformer - cascaded H-bridge rectifier, dual active bridge isolation, direct 800 VDC output - with the Faraday arithmetic, chain efficiency, capex and the honest open problems.

800 VDCAI factorydata center powerHVDCpower distributionSiCsolid-state transformerSST

Read article →

NVIDIA 800 VDC Power Architecture: Advantages for AI Data Centers

Shopify API

Why 54 V racks hit a wall at 200 kW, what the 800 VDC chain changes between grid and GPU, and the arithmetic behind the 5% efficiency, 45% copper, and 70% maintenance claims - plus the four problems it leaves unsolved.

800 VDCAI factorydata center powerHVDCKyberNVIDIApower distributionRubin Ultra

Read article →

How Air Cleanliness Affects Servers in a Data Center

Shopify API

ISO Class 8 particulate limits, ANSI/ISA-71.04 G1 gaseous limits, and the five ways contamination kills servers: heat sink fouling, zinc whiskers, creep corrosion, fibre end faces, and filter bypass. With computed filtration and energy numbers.

air qualitycontamination controlcreep corrosiondata center filtrationISO 14644MERV filtrationzinc whiskers

Read article →

ATS vs STS in Data Centers: What Actually Changes the Design

Shopify API

ATS vs STS in data centers: where each transfer switch belongs in the power chain, why an STS needs two live sources, what the 4 ms transfer means against the ITIC window, and the SCR loss the ATS never pays.

AI data centerATSNFPA 110power distributionSTSTier IIItransfer switchUL 1008

Read article →

GPU Server Burn-In Testing: What to Run Before Racking

Shopify API

What to run on a GPU server before it carries production work: DCGM diagnostic levels, thermal soak, XID and ECC acceptance limits, NCCL bus bandwidth targets, and the exit criteria that define a pass.

acceptance testingAI clusterburn-incommissioningDCGMGPUNCCL

Read article →